Programmable Controllers
MELSEC L Series
The MELSEC-L Series will innovate and evolve your
production site.
Its site perspective achieves excellent ease-of-use.
The MELSEC-L Series has been designed based on a passion for monozukuri (creation), trustworthy technology and reliability. This concept also applies to system installation and operation.
With various I/O functions as standard inclusions, the MELSEC-L Series serves to improve work efficiency by realizing convenience, ease-of-use, and diverse control.
Convenience that fits in the palm of your hand
The L Series is a compact-class controller, part of the MELSEC products renowned for exceptional cost verses performance and strong reliability.
It provides the performance, functions, and capabilities required for today's demanding applications in a small package.
MELSEC-L Series greatly expands the range of functionality traditionally associated with compact programmable controllers and through user-centric design, pushes the limits of ease of use.
Ideally configured to satisfy the applications requirements
MELSEC L Series has been designed with three key concepts in mind.
Reliability
Robust and trusted MELSEC product quality.
Ease-of-use
Enabling engineers and programmers to do their job as efficiently as possible to reduce costs.
Flexibility
L Series is a cost-efficient control system flexible to various applications, enabling an ideal system design.
The CPU module contains a diverse range of control functions
A large variety of I/O types and features are built-in for convenience.
Due to an abundance of advanced functionality, L Series CPUs are flexible enough to meet a wide variety of needs.
High speed, large memory capacity CPU
The CPU has a basic operation processing speed of 9.5 ns*1 and 260K steps*2 of program capacity ideal for complex programs and equipment control.
*1: For L06CPU(-P),
L26CPU(-P), L26CPU-(P)BT
*2: For L26CPU(-P), L26CPU-(P)BT
Advanced capabilities focused on improving efficiency
The user-friendly display unit enables routine operations to be made without a computer. An SD memory card slot*3 is included as standard for data logging and program storage. Write programs and manage L Series controllers using GX Works2 and iQ Works, the most advanced and effective software for Mitsubishi controllers yet.
*3: Included with L02CPU(-P),
L06CPU(-P), L26CPU(-P), L26CPU-(P)BT
CPU
Module for PLC system control.
The L Series CPU features a variety of I/O functions as standard inclusions.
Customize it to include the functions that suit your application, and enable various control applications.
Branch/extension module
This module allows the system to be extended to match the size of your production facility.
Power supply
Module for electricity supply of CPU, input/output, and other modules.
I/O module
These modules use an analog method for data input/output. They achieve fine-tuned control with high-speed, high-accuracy, and high-resolution.
Analog I/O module
These modules use an analog method for data input/output. They achieve fine-tuned control with high-speed, high-accuracy, and high-resolution.
Counter module
Easily and accurately count high-speed pulse with this module.
Positioning module
Modules for high-speed, high-accuracy positioning control.
Information module
This module allows the exchange of information with the control system host.
Control network module
Interface module group for control-system networks.
Each FA level is seamlessly integrated with a diverse network.
Option
We also provide an extensive lineup of peripheral products such as connectors for input/output modules and industrial hubs.
Lineup |
Programmable
controller CPU |
Control method |
Stored program
cyclic operation |
I/O control mode |
Refresh mode |
Programming language |
Ladder diagram |
Engineering
environment |
MELSOFT GX Works2 |
Program size (K
step) |
260 |
Number of I/O points
[X/Y] (point) |
4096 |
Device/label memory/
standard RAM (K byte) |
768 |
Data memory/
standard ROM (byte) |
2 M |
Processing speed |
|
LD instruction (ns) |
9.5 |
MOV instruction (ns) |
19 |
Floating point
addition (µs) |
0.057 |
Memory interface |
|
Extended SRAM
cassette |
— |
SD memory card |
●*6 |
SRAM card, FLASH
card, ATA card |
— |
External interface |
|
USB |
● |
Ethernet |
●*6 |
RS-232 |
●*10 |
RS-422/485 |
— |
Display unit |
● |
CC-Link IE
connection port |
|
Ethernet |
— |
Network connectivity
(adapter/module) |
|
Ethernet |
● |
CC-Link IE Control |
— |
CC-Link IE Field |
● |
CC-Link |
● |
CC-Link/LT |
● |
SSCNET Ⅲ/H |
● |
AnyWire |
● |
BACnet™ |
● |
MODBUS®/TCP |
● |
MODBUS® |
● |
General
specifications/conformed standards |
|
Operating ambient
temperature |
0...55℃ |
International safety
standards |
— |
Standard on
corrosive atmosphere |
— |
CE: Council
Directive of the European Communities |
● |
UL: Underwriters
Laboratories Listing |
● |
LR: Lloyd's Register
of Shipping approval |
— |
DNV: Norwegian
Maritime approval |
— |
RINA: Italian
Maritime approval |
— |
NK: ClassNK approval |
— |
ABS: American Bureau
of Shipping approval |
— |
BV: Bureau Veritas
approval |
— |
GL: Germanischer
Lloyd approval |
— |
Key
features/functions |
Machine control |
*1:
Supports redundant system when paired with R6RFM
*2: SFC is not supported in redundant mode and by safety CPU
*3: Q□UDVCPU only
*4: When using CW Workbench
*5: Does not support QnUDVCPU and certain models
*6: Does not support L02SCPU(-P)
*7: Supports the user Ethernet port of Q24DHCCPU-V/VG/LS and Q26DHCCPU-LS only
*8: Supports Q□UDE(H)CPU and Q□UDVCPU only
*9: Does not support Q□UDE(H)CPU and Q□UDVCPU
*10: Supports L02SCPU(-P) only
*11: Supports FX3G only
*12: R□ENCPU only
*13: Supports the MELSEC iQ-R Series only.
*14: Supported by expansion board
*15: Does not support Q□(P)(H)CPU and Q□PRHCPU
*16: Supports SSCNET Ⅲ
*17: Only supported when used together with extended temperature range
main/extension base units
*18: R□SFCPU-SET only.
*19: For protection against aggressive atmosphere and gases, products with a
conformal coating (JIS C 60721-3-3/IEC 60721-3-3 Class 3C2) are available on
request
*20: Operating ambient temperature from -20℃ is supported by products produced from June 2016 (serial number
"166" or later). For details, on supported products, please refer to
the relevant product manual.
·
Product Comparison
Series |
Modular type |
Modular type |
Baseless type |
|
|
|
|
PAC (Programmable automation controller) |
Programmable controller CPU |
Programmable controller CPU |
|
Lineup |
Programmable
controller CPU: 8 models |
Programmable
controller CPU (Universal model): 25 models |
Programmable
controller CPU |
Control method |
Stored program
cyclic operation |
Stored program
cyclic operation |
Stored program
cyclic operation |
I/O control mode |
Refresh mode |
Refresh mode |
Refresh mode |
Programming language |
Ladder diagram |
Ladder diagram |
Ladder diagram |
Engineering
environment |
MELSOFT GX Works3 |
MELSOFT GX Works2 |
MELSOFT GX Works2 |
Program size (K
step) |
1200 |
1000 |
260 |
Number of I/O points
[X/Y] (point) |
4096 |
4096 |
4096 |
Device/label memory/
standard RAM (K byte) |
3380 |
1792 |
768 |
Data memory/
standard ROM (byte) |
40 M |
16 M |
2 M |
Processing speed |
|||
LD instruction (ns) |
0.98 |
1.9 |
9.5 |
MOV instruction (ns) |
1.96 |
3.9 |
19 |
Floating point
addition (µs) |
0.01 |
0.014 |
0.057 |
Memory interface |
|||
Extended SRAM
cassette |
● |
●*3 |
— |
SD memory card |
● |
●*3 |
●*6 |
SRAM card, FLASH
card, ATA card |
— |
●*5 |
— |
External interface |
|||
USB |
● |
● |
● |
Ethernet |
● |
●*8 |
●*6 |
RS-232 |
— |
●*9 |
●*10 |
RS-422/485 |
— |
— |
— |
Display unit |
— |
— |
● |
CC-Link IE
connection port |
|||
Ethernet |
●*12 |
— |
— |
Network connectivity
(adapter/module) |
|||
Ethernet |
● |
● |
● |
CC-Link IE Control |
● |
● |
— |
CC-Link IE Field |
● |
●*15 |
● |
CC-Link |
● |
● |
● |
CC-Link/LT |
— |
● |
● |
SSCNET Ⅲ/H |
● |
● |
● |
AnyWire |
● |
● |
● |
BACnet™ |
● |
● |
● |
MODBUS®/TCP |
● |
● |
● |
MODBUS® |
● |
● |
● |
General
specifications/conformed standards |
|||
Operating ambient
temperature |
0...55℃ (60℃*17) |
0...55℃ |
0...55℃ |
International safety
standards |
●*18 |
— |
— |
Standard on
corrosive atmosphere |
●*19 |
— |
— |
CE: Council
Directive of the European Communities |
● |
● |
● |
UL: Underwriters
Laboratories Listing |
● |
● |
● |
LR: Lloyd's Register
of Shipping approval |
● |
● |
— |
DNV: Norwegian
Maritime approval |
● |
● |
— |
RINA: Italian
Maritime approval |
● |
● |
— |
NK: ClassNK approval |
● |
● |
— |
ABS: American Bureau
of Shipping approval |
● |
● |
— |
BV: Bureau Veritas
approval |
● |
● |
— |
GL: Germanischer
Lloyd approval |
● |
● |
— |
Key
features/functions |
Line manufacturing |
Line manufacturing |
Machine control |