Start main contents

  • Register
  • Login

Print Page

Font Size:
Optional Products
Visualization
OPTIONAL PRODUCTS

Customize your monitoring system

Enhanced your SCADA system with customized options that fit your needs such as High-speed reliable data collection, energy monitoring, preventive maintenance and quality control.


Overview

High speed data acquisition × MC Historian
It is a high-performance, highly reliable data logger and it is possible to collect 100,000 points / sec * (MC Works 64's standard for trend collection performance is 20,000 points / sec * ). It is possible to log operation results by using calculation formulas. Long logging is possible due to log capacity reduction using high compression function. Moreover, it is possible to secure high reliability through redundancy function and distributed processing. 

We have products of SD version, ET version, R version according to customer's application. MC Works 64 and MC Mobile also include MC Historian Express, which is a simplified version of MC Historian. 

※ : It depends on the system configuration.


Energy monitoring × AX Energy
You can visualize and analyze energy consumption and CO 2 emissions of electricity, gas, etc. in units of plant, equipment and equipment, and reduce costs by reducing wasteful energy consumption. You can graph the energy consumption on a daily or monthly basis and switch them easily by switching them. Forms of any format can be created with Microsoft® Excel®.



Preventive Maintenance × AX Facility
We set up and utilize the know-how of customer's troubleshooting at the time of trouble, and support early restoration at the time of equipment trouble. Analyze the cause of failure of equipment and the number of occurrences, grasp the tendency and prevent and preserve. As a result of analyzing, you can create a form of any format with Microsoft® Excel®.


Quality control × AX Quality
Quality control, process charts to analyze the process capability, create work charts, reduce the labor of field operators and managers. We provide SQC / SPC data analysis, SQC chart, report, SPC rule based alarm.



Web surveillance × AX Portal
MC Works 64, AX Energy, AX Facility, AX Quality screen can be monitored on the Web browser.
You can split the screen and integrate and display those functions.


Product Lineup


Specification

Operating environment

System requirements

item

MC Works 
64 
MC Graph 64 MC Alarm 64

MC Historian

MC Mobile

AX Energy 
AX Facility 
AX Quality 
AX Portal

series

PC / AT compatible personal computer

CPU

Dual / Multi Core 64-bit processor 2 GHz or higher recommended

memory

4 GB (8 GB or more recommended)

4 GB (10 GB or more is recommended)

Hard disk drive 
(during installation)

4 GB or more free space

160 GB or more free space

4 GB or more free space

Free space of 20 GB or more 
(50 GB or more is recommended)

Virtual memory (during operation)

512 MB or more

Disk drive

DVD-ROM drive

OS * 1

64 bit Windows® OS

display

Resolution 1024 × 768 pixels or more

Database * 1

Microsoft® SQL Server®

.NET Framework

4.5

Web server * 2

Microsoft® Internet Information Services (IIS) 7.0 or later

Web browser * 1 ※ 2

Silverlight® compatible browser (Internet Explorer®, etc.)

Other requirements

-

-

-

SharePoint® Microsoft® 
Server 2012 
※ 4

Microsoft® SharePoint® 
Server 2010 and SharePoint® 
Foundation 2010 
* 4

Microsoft® Office Excel® 
(2003 or later) 
* 3

Sequencer 
engineering 
software 
# 5

GX Works 2 (1.545 T or later) 
GX Works 3 (1.025 B or later)

-

-

-

* 1 : Refer to the following table for details of version compatibility.

* 2 : It is necessary to see the browser screen.

* 3 : It is necessary for using the report.

* 4 : AX Portal is compatible.

* 5 : Required for automatically generating sequencer project with MC AppBuilder.

 

OS compatible

OS

MC Works 
64 
MC Graph 64 MC Alarm 64

MC Historian

MC Mobile

AX Energy 
AX Facility 
AX Quality 
AX Portal

Windows® 10

The server function can be installed only on Windows Server OS.

Windows® 8, 8.1 * 1

Windows® 7 SP1 ※ 2

* 1 : Only Pro and Enterprise editions are compatible.

* 2 : Only Professional, Enterprise, Ultimate editions are compatible.

 

Database compatibility (data storage)

Database

MC Works 
64 
MC Graph 64 MC Alarm 64

MC Historian

MC Mobile

AX Energy

AX Facility 
AX Quality 
AX Portal

SQL Server® 2014 * 2

● ● 1

SQL Server® 2012 ※ 2

● ● 1

SQL Server® 2008 R2 * 2

● ● 1

* 1 : AX Energy operates in demo mode only for 180 days when using SQL Server® Express.

* 2 : You can use Express version of Express. Please be aware, however, that there are restrictions on using SQL Server® Express. 
(Database size: up to 10 GB, etc. There are restrictions etc. For details please check on the website of Microsoft®, etc.)

 

Web browser compatible (screen display)

Web browser

MC Works 
64 
MC Graph 64 MC Alarm 64

MC Historian

MC Mobile

AX Energy 
AX Facility 
AX Quality 
AX Portal

Internet Explorer® 8-11

Firefox® 3 or higher

※ 1

※ 1

Safari®

※ 1

※ 1

Google Chrome®

-

-

Other browsers 
(Silverlight® compatible)

※ 1

※ 1

-

* 1 : Only the HMI screen of Silverlight® version is displayed.

 

Selection Tool

Selecting SCADA Products

1. MC Works64 server (if MC Works64 is not required, but data collection function is needed, go to 2 and select MC Historian)

 

2. MC Historian servers (if data collection is not needed, or if the collection speed is 50k points per minute or less, use the trend functions of MC Works64. Go to 3)

 


3. MC Works64/MC Historian client. (If no client needed, go to 4)

 

4. MC Historian remote collector (If not needed, go to 5)

 



5. MC Mobile (If not needed, go to 7)

 


6. Additional MC Mobile Licenses (If mobile device monitoring not needed, go to 7)


7. MC Works64 license authentication

MC Works USB Key: If using different personal computers for development and runtime (display function) and want to use one license (a USB key is used for H/W license authentication). If using the same personal computer for development and runtime (display function), use the Internet for the S/W license authentication, and the MC Works USB Key is not needed.


8. Japanese-language and Chinese-language package products (If not needed, go to 9.)

MC Works64 Language Pack: Japanese language or Chinese language package.


9. MC Alarm MMX (If not needed, go to 10.)

MC Alarm MMX LT: Advanced E-mail notification with features such as utilizing a schedule, alarm acknowledgment, etc.

(Note: Basic E-mail features are included in the standard features of MC Works64)


10. BridgeWorX (If not needed, go to 11.)

BridgeWorX Server: Data conversion function (1 transaction)

BridgeWorX Lite: Data conversion function (5 transactions)

BridgeWorX Standard: Data conversion function (25 transactions)

BridgeWorX Enterprise: Data conversion function (1000 transactions)


11. ReportWorX

ReportWorX Server: Full-fledged form handling processes (1 report) 

ReportWorX Lite: Full-fledged form handling processes (5 reports) 

ReportWorX Standard: Full-fledged form handling processes (25 reports) 

ReportWorX Enterprise: Full-fledged form handling processes (1000 reports)


Others

AnalytiX® products

 

Item name

Model name

Asset  1

Overview

AX Energy SV

SW3DND-AXESV-E

Five

Energy monitoring 
+ MC Historian SD (5 tags included) 
+ ReportWorX (1 report) 
(MC Works 64 license required separately)

AX Energy  2

SW 3 DND-AXE-E

Five

Energy monitoring 
+ MC Works 64 DV (75 tags included) 
+ MC Historian SD (5 tags included) 
+ 1 MC Works 64 CL RT 
+ ReportWorX (1 report)

AX Energy AS

SW 3 DND - AXEAS - ET

1,100,500

Added 10, 1000, 5000 tags to MC Works 64 
+ added 1,100, 500 tags to MC Historian 
(MC Works 64 license, AX Energy license required separately)

AX Facility SV

SW 3 DND - AXFSV - E

Five

Preventive maintenance 
+ MC Historian SD (5 tags included) 
+ ReportWorX (1 report) 
(MC Works 64 license required separately)

AX Facility * 2

SW 3 DND - AXF - E

Five

Preventive maintenance 
+ MC Works 64 DV (75 tags included) 
+ MC Historian SD (5 tags included) 
+ 1 MC Works 64 CL RT 
+ ReportWorX (1 report)

AX Facility AS

SW 3 DND - AXFAS - ET

1,100, 
500, 1500, 5K, 10k

Added 10, 1000, 5000, 15000, 50000, 100000 tags to MC Works 64 
+ 1, 100, 500, 1500, 5000, 10000 tag added to MC Historian 
(MC Works 64 license, AX Facility license required separately)

AX Quality SV

SW 3 DND - AXQSV - E

-

Quality control (MC Works 64 license, MC Historian required separately) * 3

AX Quality * 2

SW3DND-AXQ-E

-

Quality control 
+ MC Works 64 (150 tags included) 
+ MC Historian (150 tags included) 
* 3

AX Portal SV

SW 3 DND - AXPSV - E

-

Web monitoring 
+ MC Works 64 CL LT (1 client) 
(MC Works 64 license is required separately)

AX Portal ET * 2

SW3DND-AXPET-E

-

Web monitoring 
+ MC Works 64 DV (15 k tag included) 
+ MC Works 64 CL LT (25 clients)

 

 

 Basic package  

 

 Additional package

 

* 1 : AX Energy / AX Facility is licensed by the number of analyzes (assets), not the number of tags.

* 2 : Japanese can not be used for MX OPC server. 
To use Japanese, please purchase the Device Explorer OPC server.

* 3 : AX Quality functions can be assigned to all MC Historian tags.

Related Solutions
Page Top