Product
Product Features
Extension power supply module
Model | Specifications | Compatible CPU module | |||
---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||
FX5-1PSU-5V | Power supply for FX5 extension module Internal 5V DC: 1.2 A *1 Internal 24 V DC: 0.3 A *1 | ○ (AC power supply type) Up to 2 modules *3 | × | ○ Up to 1 module | |
FX3U-1PSU-5V | Power supply for FX3 extension module Internal 5 V DC: 1 A *1 Internal 24 V DC: 0.3 A *1 | *2 ○ (AC power supply type) Up to 2 modules *3 | × | × | |
FX5-C1PS-5V | Power supply for FX5 extension module [Output current] 5 V DC: 1200 mA *1 24 V DC: 625 mA *1 | *4 | ○ Up to 2 modules | × |
- : Maximum output current depends on the ambient temperature.
- : When connecting to FX5U, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
- : Max. of total two FX5-1PSU-5V and FX3U-1PSU-5V can be connected in one system.
- : When connecting to FX5U, FX5-CNV-IF is required.
Connector conversion module
Model | Specifications | Compatible CPU module | |||
---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||
FX5-CNV-IF | Connector conversion module used from FX5 (extension cable type) to connect FX5 (extension connector type) extension modules. Control power: not consumed | ○ Up to 1 module | × | ○ Up to 1 module | |
FX5-CNV-IFC | Connector conversion module used from FX5 (extension connector type) to connect FX5 (extension cable type) extension modules. Control power: not consumed | × | ○ Up to 1 module | × |
Connector conversion adapter
Model | Specifications | Compatible CPU module | |||
---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||
FX5-CNV-BC | Connector conversion adapter | ○ Up to 1 module | ○ Up to 1 module | ○ Up to 1 module |
Extension cable
Model | Length | Application | Compatible CPU module | |||
---|---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | ||||
FX5-30EC | 0.3m | Extension cable for extension module | ○ Up to 1 module | ○ Up to 1 module | ○ Up to 1 module | |
FX5-65EC | 0.65m |
Bus conversion module
Model | Specifications | Compatible CPU module | |||
---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||
FX5-CNV-BUS | Bus conversion FX5 (extension cable type) -> FX3 extension Control power: 5 V DC 150 mA (supplied from PLC) | ○ Up to 1 module | *1 ○ Up to 1 module | × | |
FX5-CNV-BUSC | Bus conversion FX5 (extension connector type) -> FX3 extension Control power: 5 V DC 150 mA (supplied from PLC) | *2 ○ Up to 1 module | ○ Up to 1 module | × |
- : FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to FX5UC.
- : FX5-CNV-IF is necessary to connect to FX5U.
Terminal modules
Terminal modules are used to convert connector-type I/O terminals into terminal blocks.
By using terminal blocks (built-in element type) dedicated to input or output, capturing of AC input signals and format conversion into the relay/transistor/triac output can be performed.
Model | No. of input points | No. of output points | Function | |
---|---|---|---|---|
FX-16E-TB | 16 input points or 16 output points | Directly connected to the I/O terminal of PLC. Using this unit instead of a terminal block or relaying a wiring of I/O device located remotely from PLC enables reducing of the man-hours of I/O wiring. | ||
FX-16E-TB/UL | ||||
FX-32E-TB | 32 input points, 32 output points, or 16 input points and 16 output points | |||
FX-32E-TB/UL | ||||
FX-16EYR-TB | - | 16 points | Relay output type | |
FX-16EYR-ES-TB/UL | ||||
FX-16EYS-TB | Triac output type | |||
FX-16EYS-ES-TB/UL | ||||
FX-16EYT-TB | Transistor output type (sink) | |||
FX-16EYT-ES-TB/UL | ||||
FX-16EYT-ESS-TB/UL | Transistor output type (source) |
SD memory card
Model | Specifications | Compatible CPU module | ||||
---|---|---|---|---|---|---|
Type | Capacity | Number of writes | FX5U | FX5UC | FX5UJ | |
NZ1MEM-2GBSD | SD memory card | 2G bytes | 60,000 times | ○ Up to 1 module | ○ Up to 1 module | ○ Up to 1 module |
NZ1MEM-4GBSD | SDHC memory card | 4G bytes | 100,000 times | |||
NZ1MEM-8GBSD | 8G bytes | |||||
NZ1MEM-16GBSD | 16G bytes |
Battery
Model | Application | Compatible CPU module | |||
---|---|---|---|---|---|
FX5U | FX5UC | FX5UJ | |||
FX3U-32BL | The battery will be used when you desire to retain (latch) * the status of the device memory or clock data before a power failure. At the time of delivery from a plant, the battery is not built in the CPU module. Please make arrangements if required. | ○ Up to 1 module | ○ Up to 1 module | × |
- : Setting of parameter is required for a power failure retention.
Cable
Model | Length | Application | |
---|---|---|---|
FX-232CAB-1 | 3.0 m | Use a communication cable to connect a PLC with a personal computer by RS-232C communication. FX5-232ADP <-> Personal computer FX5-232-BD * <-> Personal computer |
- : FX5-232-BD can be connected to the FX5U/FX5UJ CPU module.